﻿id	summary	reporter	owner	description	type	status	priority	milestone	component	version	resolution	keywords	cc
11104	[IE] Focusing widget will reset editor scrollbar position	Marek Lewandowski	Piotrek Koszuliński	"
since: '''4.3''' until '''major'''[[BR]]

If you will scroll your content all the way down, blur editor, and click directly to widget (to focus it) - editor scrollbar will jump to topmost position. It happens regardless of widget type.

1. open image2 sample
2. scroll editor to its very bottom
3. '''blur editor''' (i.e. click on sample title)
4. click directly on any image widget

'''Expected result:'''[[BR]]
Clicked widget should simply be focused.

'''Current result:'''[[BR]]
Scrollbar is moved to top, in addition to that widget is not being focused, because caret goes to begining of the document.
"	Bug	closed	Normal	CKEditor 4.3.3	General	4.3 Beta	fixed	IE9 IE10	